Drain Valves Complete drainage is assured by double action of the valve, which opens when the compressor starts and stops. Long, trouble-free service is provided through simplicity of design and the use of rust-resisting materials. A minimum pressure of 30 PSI is required to permit this valve to function properly. Maximum operating pressure 300 PSI. Use of Fig. 504 recommended on air compressors with 5 horsepower or less. Temp. range -40°F to 225°F. Graph K
|
Model 620-3 Installation Instructions INSTRUCTIONS FOR INSTALLATION It is recommended that the tank drain be opened to below off exiting water, oil and scale before the Automatic Drain Value is installed. 1. Connect 3/8" drain valve inlet (1) to the
manual drain valve on the bottom of the tank. Use pipe fitting to adapt.
(illustration "C") NOTE: State of Calif. code requires a manual "bypass" drain valve be installed in conjuction with automatic drain valves. The kingston Fig. 504 can satisfy this requirement. Re: Title 8, Section 465(a) unfired pressure vessel safety orders. |
|